Publicaciones

Esta sección ofrece el acceso a la base de datos de Publicaciones que recopila los artículos del IAC publicados en revistas científicas. Por favor, pulsa la flecha del menú para ver todas las opciones de búsqueda y de ordenación de resultados; autor, revista, año, etc..

Además ofrece acceso al  repositorio de preprints del IAC: https://research.iac.es/preprints/l

  • Diagnostics of the Ionized ISM: The Importance of Density Fluctuations
    It is well known that when measuring electron densities in H II regions locally via emission line ratios the values observed are 100cm-3, but gobal values obtained via emission measure using surface brightness as the observed parameter are ~1cm-3. This difference is attributable to density fluctuations,and traditional models for these is the `
    Beckman, J. E. et al.

    Fecha de publicación:

    12
    2005
    Número de citas
    0
  • Diagnostic diagrams of H 0 regions in the Local Group
    We have studied here for the first time the use of the log(H 0/[N 0]), log (H 0/[S 0]) diagnostic diagram for determining the metallicities and ionization parameters of the H 0 regions in the Local Group. An important advantage of using these lines is their proximity in wavelength, which both simplifies the observations and makes the de-reddening
    Delgado, G. et al.

    Fecha de publicación:

    12
    2005
    Número de citas
    1
  • Comparison of the Hα Equivalent Width of H II Regions in a Flocculent and a Grand-Design Galaxy: Possible Evidence for Initial Mass Function Variations
    We present here a study of the Hα equivalent widths of the flocculent galaxy NGC 4395 and the grand-design galaxy NGC 5457. A difference between the mean values of the Hα equivalent widths for the two galaxies has been found. Several hypotheses are presented in order to explain this difference: differences in age, metallicity, star formation rate
    Cedrés, Bernabé et al.

    Fecha de publicación:

    12
    2005
    Número de citas
    11
  • CCDs and CCD controllers for the GTC Day One
    The need of the GTC for acquisition cameras, wavefront sensors and scientific instrumentation operating in the optical wavelength range has led to the acquisition of various CCDs and CCD controllers. Due to stringent science, mechanical and ambient requirements the initial idea to employ a general purpose controller had been dropped in favor of two
    Kohley, R. et al.

    Fecha de publicación:

    12
    2005
    Número de citas
    1
  • Calibration of the SDSS/SEGUE Spectroscopic Pipeline
    We describe an ongoing effort to validate the estimated atmospheric parameters (Teff, log g, [Fe/H]) obtained from SDSS spectroscopy (R = 2000) and ugriz photometry, which are being employed for both the previous SDSS-I and the ongoing SEGUE surveys. The spectroscopic pipeline makes use of a number of methods for the estimation of each parameter
    Sivarani, T. et al.

    Fecha de publicación:

    12
    2005
    Número de citas
    2